Revit Stairs Interesting fact about risers

If you create a stair that starts at Level 0 and rises to Level 1 using the boundary and riser method of skeching (or probable any method, then change the height of the first floor, the stair risers will only change if the stair type has a maximum riser height set to an amount that can accomodate the change. In other words make sure you have the maximum riser height set already to an amount that works for the building.

If you want to change the maximum riser height later, you will need to duplicate the stair type. If you try to change the maximum riser height of the existing stair, nothing will happen. Beware.